zabbix通过snmp来监控dell的idrac
原作来自zabbix论坛,改进版来自后附github的地址,本地是整理后的版本,增加了value mapping的内容,已经作为README的更新提交给作者。
模版请查看附件[Template_Dell_iDRAC_SNMPv2.zip],或者去gitlab下载。
Menu: Administration->General->Value mapping->Create value map CONFIGURATION OF VALUE MAPPING notice: 1) use Template_Dell_iDRAC_SNMPv2.zbx.xml 2) website: https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idrac add k/v(s) as given below: -------------------------- DellDracDiskState 1 -> Unknown 2 -> Ready 3 -> Online 4 -> Foreign 5 -> Offline 6 -> Blocked 7 -> Failed 8 -> Non-RAID 9 -> Removed Dell iDRAC Network Device Connection Status 1 -> Down 2 -> Up Dell Open Manage System Status 1 -> Other 2 -> Unknown 3 -> OK 4 -> NonCritical 5 -> Critical 6 -> NonRecoverable DellPowerState 1 -> Other 2 -> Unknown 3 -> Off 4 -> On Dell PSU State Settings 1 -> Unknown 2 -> Online (state disabled) 4 -> not Ready 8 -> Fan Failure 10 -> Online and Fan Failure 16 -> On 242 -> Online and OK DellRaidLevel 1 -> Unknown 2 -> RAID-0 3 -> RAID-1 4 -> RAID-5 5 -> RAID-6 6 -> RAID-10 7 -> RAID-50 8 -> RAID-60 9 -> Concatenated RAID 1 10 -> Concatenated RAID 5 DellRaidVolumeState 1 -> Unknown 2 -> Online 3 -> Failed 4 -> Degraded Dell_PSU_SensorState 1 -> Presence Detected 2 -> PS Failure 4 -> Predictuve Failure 8 -> PS AC lost 16 -> AC lost or out of range 32 -> AC out of range but still present --------------------------
原文地址:http://nosmoking.blog.51cto.com/3263888/1696018