dell服务器硬盘的状态变成外来(foreign)命令行修复

时间:2016-11-24 00:09:22      阅读:1887      评论:0      收藏:0      [点我收藏+]

标签:reblid megacli dell

Idrac监控报错:登陆ideac卡后如下如所示:硬盘状态是红叉,状态是外来

技术分享命令行安装MegaCli

rpm -ivh MegaCli-8.07.08-1.noarch.rpm 

查看包的安装路径

rpm -ql MegaCli-8.07.08-1.noarch

/opt/MegaRAID/MegaCli/MegaCli

/opt/MegaRAID/MegaCli/MegaCli64

/opt/MegaRAID/MegaCli/libstorelibir-2.so.14.07-0

执行状态检测命令:

/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall |grep ‘Firmware state‘

Firmware state: Unconfigured(good), Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

执行导入命令

/opt/MegaRAID/MegaCli/MegaCli64  -CfgForeign -Import -aall        

Foreign configuration is imported on controller 0.

Exit Code: 0x00

再次执行状态检测命令:

/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall |grep ‘Firmware state‘

Firmware state: Rebuild

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

Firmware state: Online, Spun Up

查询 Rebuild 进度:

/opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -showprog  -physdrv[32:0] -a0         

显示如下:                          

Rebuild Progress on Device at Enclosure 32, Slot 0 Completed 38% in 54 Minutes.

Exit Code: 0x00

或者

/opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -ProgDsply  -physdrv[32:0] -a0

显示如下:

      Rebuild progress of physical drives...


  Enclosure:Slot               Percent Complete                       Time Elps

       032 :00     ####################***40 %*********************** 00:56:40


    Press <ESC> key to quit...


备注:

Enclosure Device ID: 32

Slot Number: 0

以上两条信息通过/opt/MegaRAID/MegaCli/MegaCli64 -pdlist -aall |less  来查看




扫描外来配置的个数:

# /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -scan -a0

清除外来配置:

# /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -clear -a0

再次扫描外来配置的个数:

# /opt/MegaRAID/MegaCli/MegaCli64 -cfgforeign -scan -a0 














1.显示Rebuid进度

/opt/MegaRAID/MegaCli/MegaCli64 -PDRbld -ShowProg -physdrv[20:2] -aALL

2.查看E S

/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll -NoLog | grep -Ei "(enclosure|slot)"

3.查看所有硬盘的状态

/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll -NoLog

4.查看所有Virtual Disk的状态

/opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aAll -NoLog

RAID Level对应关系:

RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0

RAID 1

RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0

RAID 0

RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3

RAID 5

RAID Level : Primary-1, Secondary-3, RAID Level Qualifier-0

RAID 10

5.在线做Raid

/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r0[0:11] WB NORA Direct CachedBadBBU -strpsz64 -a0 -NoLog
/opt/MegaRAID/MegaCli/MegaCli64 -CfgLdAdd -r5 [12:2,12:3,12:4,12:5,12:6,12:7] WB Direct -a0

6.点亮指定硬盘(定位)

/opt/MegaRAID/MegaCli/MegaCli64 -PdLocate -start -physdrv[252:2] -a0

7.清除Foreign状态

/opt/MegaRAID/MegaCli/MegaCli64 -CfgForeign -Clear -a0

8.查看RAID阵列中掉线的盘

/opt/MegaRAID/MegaCli/MegaCli64 -pdgetmissing -a0

9.替换坏掉的模块

/opt/MegaRAID/MegaCli/MegaCli64 -pdreplacemissing -physdrv[12:10] -Array5 -row0 -a0

10.手动开启rebuid

/opt/MegaRAID/MegaCli/MegaCli64 -pdrbld -start -physdrv[12:10] -a0

11.查看Megacli的log

/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog dsply -a0 > adp2.log

12.设置HotSpare

/opt/MegaRAID/MegaCli/MegaCli64-pdhsp -set[-Dedicated[-Array2]][-EnclAffinity][-nonRevertible]-PhysDrv[4:11]-a0
/opt/MegaRAID/MegaCli/MegaCli64-pdhsp -set[-EnclAffinity][-nonRevertible]-PhysDrv[321}]-a0

 

MegaCli -PDHSP   -Set   -Dedicated  -Array0  -physdrv[E:S] -a0   添加局部热备盘,其中array0表示第0个raid 

MegaCli  -pdhsp  -set   -physdrv[E:S]  -a0                                       添加全局热备盘

MegaCli  -pdhsp  -rmv  -physdrv[E:S]  -a0                                      移除全局和热备局部热备

 

13.关闭Rebuild

/opt/MegaRAID/MegaCli/MegaCli64 -AdpAutoRbld -Dsbl -a0

14.设置rebuild的速率

/opt/MegaRAID/MegaCli/MegaCli64 -AdpSetProp RebuildRate -30 -a0

 

 

附其他详细命令:

1. 常用命令:

#/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aALL  查raid级别

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL  查raid卡信息

#/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL  查看硬盘信息

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aAll  查看电池信息

#/opt/MegaRAID/MegaCli/MegaCli64 -FwTermLog -Dsply -aALL  查看raid卡日志

#/opt/MegaRAID/MegaCli/MegaCli64 -adpCount  【显示适配器个数】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetTime –aALL  【显示适配器时间】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aAll  【显示所有适配器信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -LALL -aAll  【显示所有逻辑磁盘组信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aAll  【显示所有的物理信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuDesignInfo -aALL 【显示BBU设计参数】

#/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -GetBbuProperties -aALL 【显示当前BBU属性】

#/opt/MegaRAID/MegaCli/MegaCli64 -cfgdsply -aALL 【显示Raid卡型号,Raid设置,Disk相关信息】

#/opt/MegaRAID/MegaCli/MegaCli64 -adpallinfo -aall|grep -i temp  查看温度

 

2.  磁带状态的变化,从拔盘,到插盘的过程中

Device |Normal|Damage|Rebuild|Normal

Virtual Drive |Optimal|Degraded|Degraded|Optimal

Physical Drive |Online|Failed –> Unconfigured|Rebuild|Online

 

3. 查看磁盘缓存策略

#/opt/MegaCli -LDGetProp -Cache -L0 -a0

or

#/opt/MegaCli -LDGetProp -Cache -L1 -a0

or

#/opt/MegaCli -LDGetProp -Cache -LALL -a0

or

#/opt/MegaCli -LDGetProp -Cache -LALL -aALL

or

#/opt/MegaCli -LDGetProp -DskCache -LALL -aALL

 

4.设置磁盘缓存策略

缓存策略解释:

WT (Write through

WB (Write back)

NORA (No read ahead)

RA (Read ahead)

ADRA (Adaptive read ahead)

Cached

Direct

例子:

#/opt/MegaCli -LDSetProp WT|WB|NORA|RA|ADRA -L0 -a0

or

#/opt/MegaCli -LDSetProp -Cached|-Direct -L0 -a0

or

enable / disable disk cache

#/opt/MegaCli -LDSetProp -EnDskCache|-DisDskCache -L0 -a0

 

/opt/MegaRAID/MegaCli/MegaCli64 -DiscardPreservedCache -Lall -a0 -NoLOG    【清空缓存】

 

5. 创建一个 raid5 阵列,由物理盘 2,3,4 构成,该阵列的热备盘是物理盘 5

#/opt/MegaCli -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -Hsp[1:5] -a0

6. 创建阵列,不指定热备

#/opt/MegaCli -CfgLdAdd -r5 [1:2,1:3,1:4] WB Direct -a0

7. 删除阵列

#/opt/MegaCli -CfgLdDel -L1 -a0

8. 在线添加磁盘

#/opt/MegaCli -LDRecon -Start -r5 -Add -PhysDrv[1:4] -L1 -a0

9. 阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。

#/opt/MegaCli -LDInit -ShowProg -LALL -aALL

或者以动态可视化文字界面显示

#/opt/MegaCli -LDInit -ProgDsply -LALL -aALL

10. 查看阵列后台初始化进度

#/opt/MegaCli -LDBI -ShowProg -LALL -aALL

或者以动态可视化文字界面显示

#/opt/MegaCli -LDBI -ProgDsply -LALL -aALL

11. 指定第 5 块盘作为全局热备

#/opt/MegaCli -PDHSP -Set [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0

12. 指定为某个阵列的专用热备

#/opt/MegaCli -PDHSP -Set [-Dedicated [-Array1]] [-EnclAffinity] [-nonRevertible] -PhysDrv[1:5] -a0

13. 删除全局热备

#/opt/MegaCli -PDHSP -Rmv -PhysDrv[1:5] -a0

14. 将某块物理盘下线/上线

#/opt/MegaCli -PDOffline -PhysDrv [1:4] -a0

 

15. 查看物理磁盘重建进度

#/opt/MegaCli -PDRbld -ShowProg -PhysDrv [1:5] -a0