-----查看hp 集群状态信息

# cmviewcl -v

CLUSTER        STATUS      
dbsvr          up          
 
  NODE           STATUS       STATE       
  db01           up           running     
   
    Cluster_Lock_LVM:
    VOLUME_GROUP          PHYSICAL_VOLUME       STATUS             
    /dev/vglock           /dev/dsk/c6t0d1       up                 
   
    Network_Parameters:
    INTERFACE    STATUS       PATH                NAME        
    PRIMARY      up           0/0/6/1/0           lan3        
    PRIMARY      up           0/0/12/1/0          lan4        
    STANDBY      up           0/0/14/1/0          lan5        

    PACKAGE        STATUS       STATE        AUTO_RUN     NODE       
    pkg1           up           running      enabled      db01       
     
      Policy_Parameters:
      POLICY_NAME     CONFIGURED_VALUE
      Failover        configured_node
      Failback        manual
     
      Script_Parameters:
      ITEM       STATUS   MAX_RESTARTS  RESTARTS   NAME
      Service    unknown  0             0          dbservice
      Subnet     up                                10.100.1.0
     
      Node_Switching_Parameters:
      NODE_TYPE    STATUS       SWITCHING    NAME
      Primary      up           enabled      db01 (current)
      Alternate    up           enabled      db02
 
  NODE           STATUS       STATE       
  db02           up           running     
   
    Cluster_Lock_LVM:
    VOLUME_GROUP          PHYSICAL_VOLUME       STATUS             
    /dev/vglock           /dev/dsk/c6t0d1       up                 
   
    Network_Parameters:
    INTERFACE    STATUS       PATH                NAME        
    PRIMARY      up           0/0/6/1/0           lan3        
    PRIMARY      up           0/0/12/1/0          lan4         
    STANDBY      up           0/0/14/1/0          lan5        
#

------停止包

cmhaltpkg pkg1

 

-----把包挂到其它节点上:

cmrunpkg pkg1 -n db01 


------hpux 下查看内存的的大小的几种方法:

 

# /opt/ignite/binpa/print_manifest|grep Memory
NOTE: Could not read the /etc/resolv.conf file.
    Main Memory:        1024 MB

 

# /opt/ignite/binpa/print_manifest|grep Memory|awk ‘{print $3}‘
NOTE: Could not read the /etc/resolv.conf file.
1024
#

安腾主机用machinfo

machinfo | grep Memory


# echo "selall;info;wait;infolog;view;done" | /usr/sbin/cstm | grep "Total Configured Memory"
    Total Configured Memory   : 1024 MB
#

 

# echo `dmesg |grep Physical|awk ‘{print $2}‘`/1024|bc