HP Array Configuration Utility CLI for Linux 64-bit
rpm –ivh hpacucli-9.40-12.0.x86_64
/usr/sbin/hpacucli ctrl slot=0 pd all show
192.168.2.49 [~] 2015-12-22 10:03:17
root@pts/0 # /usr/sbin/hpacucli ctrl slot=0 pd all show
Smart Array P420i in Slot 0 (Embedded)
array A
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 600 GB, Predictive Failure)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SAS, 600 GB, OK)
physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 600 GB, OK)
physicaldrive 2I:2:6 (port 2I:box 2:bay 6, SAS, 600 GB, OK)
physicaldrive 2I:2:7 (port 2I:box 2:bay 7, SAS, 600 GB, OK)
physicaldrive 2I:2:8 (port 2I:box 2:bay 8, SAS, 600 GB, OK)
/usr/sbin/hpacucli ctrl all show config detail
192.168.2.49 [~] 2015-12-22 10:12:39
root@pts/0 # /usr/sbin/hpacucli ctrl all show config detail
Smart Array P420i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 001438027ABAF70
Cache Serial Number: PBKUC0BRH5K0GJ
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 4.68
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 10% Read / 90% Write
Drive Write Cache: Enabled
Total Cache Size: 1024 MB
Total Cache Memory Available: 816 MB
No-Battery Write Cache: Enabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Spare Activation Mode: Activate on drive failure
Controller Temperature (C): 64
Cache Module Temperature (C): 32
Capacitor Temperature (C): 24
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK
Array Type: Data
Logical Drive: 1
Size: 2.2 TB
Fault Tolerance: 1+0
Heads: 255
Sectors Per Track: 63
Cylinders: 65535
Strip Size: 256 KB
Full Stripe Size: 1024 KB
Status: OK
Caching: Enabled
Unique Identifier: 600508B1001C0A0D1D39FCC928C7A1B0
Disk Name: /dev/sda
Mount Points: /boot 500 MB, / 2.2 TB, /swap 2.0 GB
OS Status: LOCKED
Logical Drive Label: A213EB0F50014380225C71D00877
Mirror Group 0:
physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 600 GB, Predictive Failure)
physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:2:4 (port 1I:box 2:bay 4, SAS, 600 GB, OK)
Mirror Group 1:
physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 600 GB, OK)
physicaldrive 2I:2:6 (port 2I:box 2:bay 6, SAS, 600 GB, OK)
physicaldrive 2I:2:7 (port 2I:box 2:bay 7, SAS, 600 GB, OK)
physicaldrive 2I:2:8 (port 2I:box 2:bay 8, SAS, 600 GB, OK)
Drive Type: Data
Caching Association: None
physicaldrive 1I:2:1
Port: 1I
Box: 2
Bay: 1
Status: Predictive Failure
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M142J90000N4101DFZ
Model: HP EG0600FCVBK
Current Temperature (C): 30
Maximum Temperature (C): 51
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 1I:2:2
Port: 1I
Box: 2
Bay: 2
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10000
Firmware Revision: HPD0
Serial Number: 85M0A0J6FTM21534
Model: HP EG0600FCSPL
Current Temperature (C): 30
Maximum Temperature (C): 34
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 1I:2:3
Port: 1I
Box: 2
Bay: 3
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M14YFT0000B410E6X9
Model: HP EG0600FCVBK
Current Temperature (C): 31
Maximum Temperature (C): 57
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 1I:2:4
Port: 1I
Box: 2
Bay: 4
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M153KL0000B410CN1H
Model: HP EG0600FCVBK
Current Temperature (C): 32
Maximum Temperature (C): 54
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:5
Port: 2I
Box: 2
Bay: 5
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M14BAM0000B410CEW5
Model: HP EG0600FCVBK
Current Temperature (C): 30
Maximum Temperature (C): 50
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:6
Port: 2I
Box: 2
Bay: 6
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M154JR0000B410DWPR
Model: HP EG0600FCVBK
Current Temperature (C): 30
Maximum Temperature (C): 55
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:7
Port: 2I
Box: 2
Bay: 7
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M153XT0000B410CLFL
Model: HP EG0600FCVBK
Current Temperature (C): 31
Maximum Temperature (C): 55
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
physicaldrive 2I:2:8
Port: 2I
Box: 2
Bay: 8
Status: OK
Drive Type: Data Drive
Interface Type: SAS
Size: 600 GB
Rotational Speed: 10500
Firmware Revision: HPD3
Serial Number: S0M14YV60000B410E770
Model: HP EG0600FCVBK
Current Temperature (C): 32
Maximum Temperature (C): 53
PHY Count: 2
PHY Transfer Rate: 6.0Gbps, Unknown
Drive Authentication Status: OK
Carrier Application Version: 11
Carrier Bootloader Version: 6
SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380
Device Number: 380
Firmware Version: RevB
WWID: 5001438027ABAF7F
Vendor ID: PMCSIERA
Model: SRCv8x6G
192.168.2.49 [/tmp] 2015-12-22 10:26:49
root@pts/0 # hpacucli
HP Array Configuration Utility CLI 9.40.12.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=> ctrl all diag file=2_49.zip //file后边 自定义文件名.zip
Generating diagnostic report...done
=> exit
192.168.2.49 [/tmp] 2015-12-22 10:27:28
root@pts/0 # ll 2_49.zip //日志就在本目录下
-rw-r--r-- 1 root root 140400 Dec 22 10:27 2_49.zip
原文地址:http://blog.51cto.com/chaichuan/2073881