S1双上行连接到S4,为了实现主备链路冗余备份及故障后的快速迁移,部署使用Smart Link 技术,
且为了进一步扩展Smart Link 的备份范围,使用Monitor Link 联动方式监控上游设备的上行链路来完善Smart Link
S1:
[S1-smlk-group1]smart-link group 1
[S1-smlk-group1]smart-link enable
运行Smart Link 需要关闭stp,华为默认开启,
[S1-smlk-group1]inter e0/0/1
[S1-Ethernet0/0/1]stp disable
[S1-smlk-group1]inter e0/0/2
[S1-Ethernet0/0/1]stp disable
[S1]smart-link group 1
[S1-smlk-group1]port Ethernet 0/0/1 master #主接口
[S1-smlk-group1]port Ethernet 0/0/2 slave #备份接口
查看: Active 为主, Inactive 为备份
[S1]display smart-link group 1
把S1的e0/0/1接口shutdown后,备份接口就会立刻切换为Active状态,默认情况下,当原主接口恢复时,主接口不会自动回切到Active 状态,需要手工配置回切功能。
设置回切功能
[S1]smart-link group 1
[S1-smlk-group1]restore enable
[S1-smlk-group1]timer wtr 30 #设置为30s
配置Monitor Link
[S2]monitor-link group 1
[S2-mtlk-group1]port e0/0/1 uplink
[S2-mtlk-group1]port e0/0/2 downlink
[S2-mtlk-group1]timer recover-time 10 #设置回切时间
原文地址:http://blog.51cto.com/laotang6/2121795