CYx63BPA BLE module IQC test guide
Test Jig setting:
1. Connect USB1 and USB2 with computer serial port (Usb1:COM2, Usb2:Com 3)
2. RF wireless connect with N4010A
3. The antennas are placed vertically
N4010A IP setting:
DTM Firmware :
Open firmwareErase.bat and FirmwareProgram.bat
Perl_Erase.pl
Perl_Program.pl
Line233 , setting DTM firmware Location
test-step
1. running test program
2. Put the gold machine on the shelf and correct it by "Cal" before the test every day. (be careful not to test the gold machine, or the gold machine will be burned again.
3. Put the Test product into the shelf and press "Test" to start the Test
4. If the test passes, the program will display "PASS" as shown in the figure below:
5. If the test fails, the program shows "Fail" as shown in the figure below:
6. The test results are in the "Test_Result" folder
Test notes
1. Don‘t change the stacking position during the test
2. Do not have wires or other metal objects around the antenna
3. The test shall be conducted in the shielded room
4. If the operator has a mobile phone, please set it in airplane mode
2018.11.23 Cypress BLE module test