码迷,mamicode.com
首页 > 其他好文 > 详细

PowerDesigner设计Name和Comment 替换

时间:2015-06-01 18:31:50      阅读:140      评论:0      收藏:0      [点我收藏+]

标签:

 

comment 是注释。name 是字段描述 

 

在 PowerDesigner中操作如下

PowerDesigner-->Tools-->Execute  Commands-->Edit/Run Scripts  下执行就OK了

执行代码--------------------------------

把comment 覆盖name  方法如下:

Option   Explicit 
ValidationMode   =   True 
InteractiveMode   =   im_Batch

Dim   mdl   ‘   the   current   model

‘   get   the   current   active   model 
Set   mdl   =   ActiveModel 
If   (mdl   Is   Nothing)   Then 
      MsgBox   "There   is   no   current   Model " 
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then 
      MsgBox   "The   current   model   is   not   an   Physical   Data   model. " 
Else 
      ProcessFolder   mdl 
End   If

Private   sub   ProcessFolder(folder) 
On Error Resume Next
      Dim   Tab   ‘running     table 
      for   each   Tab   in   folder.tables 
            if   not   tab.isShortcut   then 
                  tab.name   =   tab.comment
                  Dim   col   ‘   running   column 
                  for   each   col   in   tab.columns 
                  if col.comment="" then
                  else
                        col.name=   col.comment 
                  end if
                  next 
            end   if 
      next

      Dim   view   ‘running   view 
      for   each   view   in   folder.Views 
            if   not   view.isShortcut   then 
                  view.name   =   view.comment 
            end   if 
      next

      ‘   go   into   the   sub-packages 
      Dim   f   ‘   running   folder 
      For   Each   f   In   folder.Packages 
            if   not   f.IsShortcut   then 
                  ProcessFolder   f 
            end   if 
      Next 
end   sub

将name覆盖comment  方法如下 

 

 

Option   Explicit 
ValidationMode   =   True 
InteractiveMode   =   im_Batch

Dim   mdl   ‘   the   current   model

‘   get   the   current   active   model 
Set   mdl   =   ActiveModel 
If   (mdl   Is   Nothing)   Then 
      MsgBox   "There   is   no   current   Model " 
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then 
      MsgBox   "The   current   model   is   not   an   Physical   Data   model. " 
Else 
      ProcessFolder   mdl 
End   If

‘   This   routine   copy   name   into   comment   for   each   table,   each   column   and   each   view 
‘   of   the   current   folder 
Private   sub   ProcessFolder(folder) 
      Dim   Tab   ‘running     table 
      for   each   Tab   in   folder.tables 
            if   not   tab.isShortcut   then 
                  tab.comment   =   tab.name 
                  Dim   col   ‘   running   column 
                  for   each   col   in   tab.columns 
                        col.comment=   col.name 
                  next 
            end   if 
      next

      Dim   view   ‘running   view 
      for   each   view   in   folder.Views 
            if   not   view.isShortcut   then 
                  view.comment   =   view.name 
            end   if 
      next

      ‘   go   into   the   sub-packages 
      Dim   f   ‘   running   folder 
      For   Each   f   In   folder.Packages 
            if   not   f.IsShortcut   then 
                  ProcessFolder   f 
            end   if 
      Next 
end   sub

 

PowerDesigner设计Name和Comment 替换

标签:

原文地址:http://www.cnblogs.com/yshuaiw/p/4544438.html

(0)
(0)
   
举报
评论 一句话评论(0
登录后才能评论!
© 2014 mamicode.com 版权所有  联系我们:gaon5@hotmail.com
迷上了代码!