码迷,mamicode.com
首页 > 其他好文 > 详细

PowerDesigner 把Comment复制到name中和把name复制到Comment

时间:2015-06-02 17:40:46      阅读:107      评论:0      收藏:0      [点我收藏+]

标签:

在使用PowerDesigner对数据库进行概念模型和物理模型设计时,一般在NAME或Comment中写中文,在Code中写英文。Name用来显 示,Code在代码中使用,但Comment中的文字会保存到数据库Table或Column的Comment中,当Name已经存在的时候,再写一次 Comment很麻烦,可以使用以下代码来解决这个问题

在PowerDesigner中使用方法为:

   PowerDesigner->Tools->Execute Commands->Edit/Run Scripts

将代码Copy进去执行就可以了,是对整个CDM或PDM进行操作

  1. ‘代码一:将Name中的字符COPY至Comment中  
Option   Explicit   
ValidationMode = True
InteractiveMode = im_Batch

Dim mdl ‘ the current model

‘ get the current active model
Set mdl = ActiveModel
If (mdl Is Nothing) Then
MsgBox "There is no current Model "
ElseIf Not mdl.IsKindOf(PdPDM.cls_Model) Then
MsgBox "The current model is not an Physical Data model. "
Else
ProcessFolder mdl
End If

‘ This routine copy name into comment for each table, each column and each view
‘ of the current folder
Private sub ProcessFolder(folder)
Dim Tab ‘running table
for each Tab in folder.tables
if not tab.isShortcut then
tab.comment = tab.name
Dim col ‘ running column
for each col in tab.columns
col.comment= col.name
next
end if
next

Dim view ‘running view
for each view in folder.Views
if not view.isShortcut then
view.comment = view.name
end if
next

‘ go into the sub-packages
Dim f ‘ running folder
For Each f In folder.Packages
if not f.IsShortcut then
ProcessFolder f
end if
Next
end sub

另外在使用REVERSE ENGINEER从数据库反向生成PDM的时候,PDM中的表的NAME和CODE事实上都是CODE,为了把NAME替换为数据库中Table或Column的中文Comment,可以使用以下脚本

2.‘代码二:将Comment中的字符COPY至Name中   

Option Explicit
ValidationMode = True
InteractiveMode = im_Batch

Dim mdl ‘ the current model

‘ get the current active model
Set mdl = ActiveModel
If (mdl Is Nothing) Then
MsgBox "There is no current Model "
ElseIf Not mdl.IsKindOf(PdPDM.cls_Model) Then
MsgBox "The current model is not an Physical Data model. "
Else
ProcessFolder mdl
End If

Private sub ProcessFolder(folder)
On Error Resume Next
Dim Tab ‘running table
for each Tab in folder.tables
if not tab.isShortcut then
tab.name = tab.comment
Dim col ‘ running column
for each col in tab.columns
if col.comment="" then
else
col.name= col.comment
end if
next
end if
next

Dim view ‘running view
for each view in folder.Views
if not view.isShortcut then
view.name = view.comment
end if
next

‘ go into the sub-packages
Dim f ‘ running folder
For Each f In folder.Packages
if not f.IsShortcut then
ProcessFolder f
end if
Next
end sub

PowerDesigner 把Comment复制到name中和把name复制到Comment

标签:

原文地址:http://www.cnblogs.com/tkin/p/4546869.html

(0)
(0)
   
举报
评论 一句话评论(0
登录后才能评论!
© 2014 mamicode.com 版权所有  联系我们:gaon5@hotmail.com
迷上了代码!