一、早上一台Dell R410机器宕了~查看日志如下
Aug 12 07:21:01 192.168.30.72  
Aug 12 07:21:01 HARDWARE ERROR 
Aug 12 07:21:01 CPU 2: Machine Check Exception:                4 Bank 5: 0000000000000000
Aug 12 07:21:01 TSC 0 
Aug 12 07:21:01 192.168.30.72  
Aug 12 07:21:01 This is not a software problem!
Aug 12 07:21:01 Run through mcelog --ascii to decode and contact your hardware vendor
Aug 12 07:21:01 Kernel panic - not syncing: Uncorrected machine check
Aug 12 07:21:01 192.168.30.72  
Aug 12 08:41:46 192.168.30.72 netconsole: network logging started
Aug 12 08:46:17 192.168.30.72 netconsole: network logging started
Aug 12 08:50:31 192.168.30.72 netconsole: network logging started
Aug 12 08:59:12 ipmi message handler version 39.0
Aug 12 08:59:12 IPMI Watchdog: driver initialized
Aug 12 08:59:12 Copyright (C) 2004 MontaVista Software - IPMI Powerdown via sys_reboot.
Aug 12 08:59:12 ipmi device interface
Aug 12 08:59:12 IPMI System Interface driver.
Aug 12 08:59:13 192.168.30.72 ipmi_si: Trying SMBIOS-specified KCS state machine at I/O address 0xca8, slave address 0x20, irq 0
Aug 12 08:59:13 192.168.30.72 ipmi: Found new BMC (man_id: 0x0002a2,  prod_id: 0x0100, dev_id: 0x20)
Aug 12 08:59:13 IPMI poweroff: Found a chassis style poweroff function
Aug 12 08:59:13 192.168.30.72  IPMI KCS interface initialized

二、之后让idc机房人员查看面板上代码信息如下  
E2110
A1&A2

技术分享

三、解决办法:更换内存

四、参考来源
R410 Hardware Owners Manual.pdf